Configuration Error Alarm

acBoardConfigurationError

Alarm

acBoardConfigurationError

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.2

Description

The alarm is sent when the device's settings are invalid. The trap contains a message stating, detailing, and explaining the invalid setting.

Default Severity

Critical

Event Type

equipmentAlarm

Probable Cause

underlyingResourceUnavailable (56)

Severity

Condition

Text

Corrective Action

Critical

A configuration error was detected

"Board Config Error: A run-time specific string describing the configuration error"

1. Check the run-time specific string to determine the nature of the configuration error.
2. Fix the configuration error using the appropriate tool: Web interface, OVOC, or ini file.
3. Save the configuration and if necessary restart the device.

Note: The alarm remains in Critical severity until a device restart. A Clear trap is not sent.

After configuration error

-